Description
Feature 01. Multiporosity Structure |
|
(multiporous cancellous image x 45) |
Ti-oss is made from 100% cancellous bone without any cortical portion. Innovative pulverizing technique allows multiporous structure, maximizing blood vessel ingrowth. |
Feature 02. Pore size |
|
(Ti-oss SEM image x 100) |
(A Co. SEM image x 100) Average Ti-oss pore size is more than three times of other world leading product. This advanced manufacturing technique permits rapid absorption of blood or saline into the block
|
Feature 03. Osteoconductive surface |
|
(SEM image x 3,000) |
Low temperature processing technique allows ideal, natural surface topograph, the same as human bone, stimulating osteoblast activity. Vitrification phenomenon caused by high temperature process has been completely controlled. |
Feature 04. Octacalcium phosphate crystal |
|
(SEM image x 10,000) |
(SEM image x 50,000) Pre HA structure, octacalcium phosphate crystal is found on the surface of Ti-oss, resulting in fast bone formation.
|
Biopsy Result
|
|
Feature 05. Large volume |
|
(comparison of CC per gram) |
Unique 100% multiporous cancellous nature offers higher quantitative mass volume per gram unit, compared to other nonporous product. This leads to less material cost. |
STEP 2 | Saturate Ti-oss with patient’s blood or normal saline or PRP(platelet rich plasma)
Avoid distilled water. Fill the defect site with prepared Ti-oss mixture with a sterilized
spatula or a surgical spoon.
Do not press Ti oss as the pressure may break down the multiporosity structure.
STEP 3 | Protect the graft mass with membrane or PRP coagulation, or PRF(platelet rich fibrin).
STEP 4 | Tie up the wound carefully. Exposure to oral cavity may collect oral microorganism,
resulting in infection.
STEP 5 | 3-6 months healing time is necessay to make the functional density of bone,
depending on the number of surrounding wall.
Indication
|
– Bone regeneration and augmentation – Alveolar ridge defect – Extraction defect – Sinus augmentation – Periodontal defect |
Attention |
– Avoid pressure onto Ti oss particle to maintain multiporous nature. Breaking down of Ti oss to tiny pieces drops down the best advantages of Ti oss. |
Precautions |
– Loading pressure onto Ti oss results in tiny dust like shape. – Do not use again once the sterilized seal is open. – Do not use if shelf life cycle is expired. – Store at the temperature range of 4-30’C. – Doctors prescription is required to use Ti oss. |
Contraindications
|
Following groups are not recommended to use Ti oss. – Osteomyelitis patient – Generalized or Localized Blood dyscrasia patient – Heavy smokers – Radiation therapy patient – Diabetes – Advanced Liver or Kidney disease – Thyroidism etc. |